RXLdp Differential Pressure Transmitter
- Overview
- Applications
- Certificates & Approvals
Overview
The Ashcroft® RXLdp differential transmitter utilizes patented Si-GlasTM technology, assuring precise measurement and control at extremely low differential pressures. The unit is virtually unaffected by shock or vibration; an ideal selection when reliable pressure measurement is needed.
Key Features:
- Wide selection of output signals and differential pressure ranges
- Board level OEM versions available
Specifications:
- Accuracy: ±1% span
- Differential Pressure Ranges:
Unidirectional: 0 ... 25 Pa to 0 ... 12.5 kPa
Bidirectional: ±12.5 Pa to ±12.5 kPa - NEMA 1; stainless steel and Lexan enclosure
- Mounting: surface mount
- Output signal: current or voltage
Applications
The RXLdp is ideal where consistent, and reliable differential pressure measurement is essential:
Process Applications:
- HVAC/R
- Building Energy Management / Comfort Control Systems
- Fume Hood Control
- Clean Room / Laboratory Pressurization
- Leak Detection
- Laminar Flow
- Medical
- Velocity Measurement
Certificates & Approvals
- CE
- EAC
- RoHS